RayTek Food Safety Thermometers Thermometer User Manual


 
www.raytek.com
for up-to-the-minute features
-35ºC to 275ºC (-30ºF to 525ºF)Temperature Range
Accuracy
(Assumes ambient
operating temperature
of 23ºC ±2º (73ºF ±4ºF)
Between 0ºC and 65ºC (32ºF to 150ºF): ±1ºC (±2ºF)
Below 0ºC (32ºF): ±1ºC (±2ºF) ±0.1 degree/degree
Above 65º (150ºF): ±1.5% of reading
Response Time <500ms after initial reading
Spectral response
Emissivity
Distance to Spot Size/
Optical Resolution (D:S)
2.5:1 @ 90% energy, typical
Typical Working Range
(Target Illumination)
25mm to 250mm (1" to 10")
Illumination to IR Channel
Offset
13mm (0.52")
Temperature Range
-40ºC to 200ºC (-40ºF to 390ºF)
Accuracy
(Assumes ambient
operating temperature
of 23ºC ±2º (73ºF ±4ºF)
Between -5ºC and 65ºC (23F to 150ºF): ±0.5ºC (±1ºF)
Below -5ºC (23ºF): ±1ºC (±2ºF)
Above 65ºC (150ºF): ±1% of reading
Response Time 7-8 seconds (3 time constants)
Probe Dimensions
Diameter: 3.0mm (0.118")
Length: 80mm (3.0")
AmbientOperating Range 0ºC to 50ºC (32ºF to 122ºF)
Relative Humidity
90% (±5%) RH noncondensing
@30ºC (86ºF)
Weight/Dimensions
(with Battery)
150g (0.33lbs)
165mm x 32mm x 50mm (6.5" x 1.25" x 2")
Power 9V Alkaline
Target Illumination Light
Display Hold (7 seconds)
LCD Backlit Display
Temperature Display
4 digits, 0.1ºC resolution (0.2ºF)
CE
1 year*
Options/Accessories Replacement Probe
8-14 microns
Pre-set for foodservice applications
-20ºC to 60ºC (-4ºF to 140ºF)
Storage Temperature
Raytek Corporation
Worldwide Headquarters
1201 Shaffer Rd. PO Box 1820
Santa Cruz, CA 95061-1820 USA
Tel: 1 800 866 5478
1 831 458 1110
Fax: 1 831 425 4561
solutions@raytek.com
To find a Raytek office near you please visit www.raytek.com
Worldwide Service
Raytek offers services including emergency repairs and calibration. For more
information, contact your local office or e-mail: support@raytek.com
© 2004 Raytek Corporation 1-2101 Rev. C 8/04 Raytek and the Raytek Logo are registered
trademarks and FoodPro and FoodPro Plus are trademarks of Raytek Corporation. Specifications
subject to change without notice.
Battery Life (Alkaline) 10 hours minimum @ 23ºC (73ºF)
High Brightness LED
Minimum Target Size 12mm (0.5") Ø
Sensor Type
Repeatability
Thin-film Platinum, Class A,
Resistance Thermal Device (RTD)
Standards
Certifications
Warranty
Conforms to EN 61326-1 Electromagnetic Emissions
and Susceptibility, EN 61010-1 General Safety
Within the accuracy specifications of the unit
Probe Thermometer Infrared Thermometer
Included
Battery, Carrying Pouch, User’s Manual, Quick Start Guide
*US only. Warranty duration may vary by country.