Fault Probable Cause(s) Possible Solution
Code
1 Flash The batteries need charging. Check the battery connections. If the
There is a bad connection battery connections are good, then
to the batteries. try charging the batteries.
2 Flashes There is a bad connection on Check the left motor connections and
the left motor. wiring harnesses.
3 Flashes The left motor has a short to Contact your authorized Pride
a battery connection. Provider.
4 Flashes There is a bad connection on Check the right motor connections
the right motor. and wiring harnesses.
5 Flashes The right motor has a short to Contact your authorized Pride
a battery connection. Provider.
6 Flashes The charge inhibit has been Make sure that the battery charger
activated. is not connected to the power base.
7 Flashes There is a joystick fault. Make sure the joystick is in the center
position and then power off and on
again.
8 Flashes There is a control system fault. Check power module and joystick
module connections and wiring.
9 Flashes The park brakes have a bad Check the left and right motor
connection. connections and wiring.
10 Flashes An excessive voltage has Check the battery connections.
been applied to the control
system.