Pelco C3419M-B Personal Lift User Manual


 
8 C3419M-B (11/06)
Switch Settings
WARNING: If you are using D-type or P-type control, your system may not operate if the baud rate and address
switches are not set correctly. The switches are set at the factory at the defaults for D-type control (2400 baud and
address 1).
Table E. Switch Settings for SW2
Special Systems
Switch Number 12345678910
AD-32 Preset System ON
CM9502 Setting ON
Vicon
Not currently available; SW2-3 is reserved for future use.
Serial Port Settings
Switch Number 12345678910
RS422 OFF OFF
RS485, Four Wire OFF ON
RS485, Two Wire ON ON
D or P Protocol Baud Rate
Switch Number 12345678910
2400 Baud (Default for D-type Control) OFF OFF OFF
4800 Baud (Default for P-type Control) ON OFF OFF
9600 Baud OFF ON OFF
Video Cable Type
Switch Number 12345678910
Coax Cable OFF
UTP Cable ON
Dome Termination
Switch Number
12345678910
Terminated
ON
Not Terminated
OFF