DOUBLE INSULATED TOOLS: TOOLS WITH TWO PRONG PLUGS
4. Tools marked “Double Insulated” do not require grounding. They have a special
double insulation system which satisfies OSHA requirements and complies with
the applicable standards of Underwriters Laboratories, Inc., the Canadian
Standard Association, and the National Electrical Code. (See Figure B.)
5. Double insulated tools may be used in either of the 120 volt outlets shown in the
following illustration. (See Figure B.)
EXTENSION CORDS
1. Grounded tools require a 3-wire extension cord. Double Insulated tools can
use either a 2- or 3-wire extension cord.
2. As the distance from the supply outlet increases, you must use a heavier gauge
extension cord. Using extension cords with inadequately sized wire causes a
serious drop in voltage, resulting in loss of power and possible tool damage.
3. The smaller the gauge number of the wire, the greater the capacity of the cord.
For example, a 14- gauge cord can carry a higher current than a 16- gauge
cord.
4. When using more than one extension cord to make up the total length, make
sure each cord contains at least the minimum wire size required.
5. If you are using one extension cord for more than one tool, add the nameplate
amperes and use the sum to determine the required minimum cord size.