178
(2) When a High Performance model QCPU is used
*1 "Number of CPU modules" indicates the number set in "No. of PLC" of PLC parameter ("Multiple CPU Setting").
*2 When a module occupying two slots is mounted, the maximum number of mountable I/O modules is the number
obtained by "65 - (Number of CPU modules + 1)".
When a module occupying three slots is mounted, the maximum number of mountable I/O modules is the number
obtained by "25 - (Number of CPU modules + 2)".
*3 If a Motion CPU or PC CPU module is used in a multiple CPU system, the Q3RB, Q6RB, and Q6RP cannot be
used.
*4 Available version differs for some intelligent function modules. ( Manual for the intelligent function module used)
*5 When a CPU module occupying two slots is mounted, the slot on the right of the CPU module will be 10
H
.
When a CPU module occupying three slots is mounted, the slot on the right of the CPU module will be 20
H
.
*6 When the QA1S6ADP+A1S5B/A1S6B is used, the maximum number of extension base units is 1, and the maximum
number of I/O modules that can be mounted is 20 minus the number of CPU modules. When the QA1S6ADP-
S1+A1S5B/A1S6B is used, the maximum number of extension base units is 3, and the maximum number of I/O
modules that can be mounted is 36 minus the number of CPU modules.
Item Single CPU system Multiple CPU system Reference
System
configuration
Maximum number of
extension levels
7 levels
Page 41,
Section 3.2.1
Maximum number of
mountable I/O modules
64
65- (Number of CPU modules)
*1*2
Main base unit
*3
Q3B, Q3SB, Q3RB, Q3DB
Extension base unit
*3*6
Q5B, Q6B, Q6RB, QA1S5B, QA1S6B,
QA1S6ADP+A1S5B/A1S6B, QA6B, QA6ADP+A5B/A6B
Extension cable QC05B, QC06B, QC12B, QC30B, QC50B, QC100B
Overall extension cable
distance
Within 13.2m
Power supply module
*3
Q6P, Q6SP, Q6RP, A1S6P, A6P
Available
module
High Performance model
QCPU
Function version A or later Function version B
Page 41,
Section 3.2.1,
Page 51,
Section 3.2.3
I/O module Function version A or later
Interrupt module No function version restriction
Intelligent function module Function version A or later
Function version B or later
(Function version A or later for the
QD62, QD62D, and QD62E.)
Available
software
package
GX Developer Version 4 or later Version 6 or later
Page 65,
Section 3.4
GX Configurator-AD
SW0D5C-QADU 00A or later
*4
SW0D5C-QADU 20C or later
*4
GX Configurator-DA
SW0D5C-QDAU 00A or later
*4
SW0D5C-QDAU 20C or later
*4
GX Configurator-SC
SW0D5C-QSCU 00A or later
*4
SW0D5C-QSCU 20C or later
*4
GX Configurator-CT
SW0D5C-QCTU 00A or later
*4
SW0D5C-QCTU 20C or later
*4
Other than above
The same version can be used in both single CPU systems and multiple
CPU systems.
Concept
Number of CPU modules
and mounting position
Only 1 module in the CPU slot 4 modules in the CPU slot to slot 2
Page 47,
Section 3.2.2
I/O number assignment
Slot 0 is 00
H
.
A slot on the right of the rightmost
CPU module is 00
H
.
*5
Page 27,
Section 2.2
Restrictions on number of
mountable modules
The number of mountable
modules differs depending on the
CPU module type.
The number of mountable
modules per system and the
number of controllable modules
per CPU module differ depending
on the CPU module type.
Page 69,
Section 3.5
(1) (b)