10. TRANSMITTER INSTALLATION OPTIONS
12. INSTALLING MULTIPLE TRANSMITTERS
9. APPLY POWER - SELECT DIALING METHOD
11. INSTALLING SINGLE TRANSMITTERS
WHEN IT IS INSTALLED
WITH THE JUMPER SET
FOR INSTANT
IT WILL
FUNCTION
AS ACTIVITY
FOR DXS-31 STATIONARY TRANSMITTERS
WHEN IT IS INSTALLED
WITH THE JUMPER SET
FOR DELAY
IT WILL
FUNCTION
AS EMERGENCY
WHEN IT IS
INSTALLED
WITH THE
RIGHT BUTTON
IT WILL ONLY
ACTIVATE
USING BOTH
BUTTONS
FOR ALL TWO-BUTTON TRANSMITTERS
WHEN IT IS
INSTALLED
WITH THE
LEFT BUTTON
IT WILL
ACTIVATE
USING
EITHER
BUTTON
FOR MODEL DXS-32: CUT JUMPER (INSTANT TX) FOR USE
AS AN ACTIVITY TX. SEE DXS-32 INSTALLATION INSTRUCTIONS
ADDS MULTIPLE TRANSMITTERS
PRESS TEST BUTTON
• 4 BEEPS SOUND
(TEST MODE)
3
2
ACTIVATE TRANSMITTER
• 1 BEEP SOUNDS
(TX ADDED)
REPEAT STEPS 2 & 3 FOR
ADDITIONAL TRANSMITTERS
(UP TO 16 TOTAL)
1
PRESS TEST BUTTON AGAIN
• 5 BEEPS SOUND
(ADD TX MODE)
4
NOTE: IF THE CONSOLE'S MEMORY
IS FULL, ONE LONG BEEP SOUNDS
WHEN TRYING TO ADD A TRANSMITTER
PRESS CLEAR TO RETURN TO OPERATE MODE
• 2 BEEPS SOUND WITH ACTIVITY TIMER ENABLED
• 3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED
5
DXS-62A
NOTE: EACH TIME THE TEST BUTTON IS PRESSED IN THE ADD TX MODE,
THE CONSOLE WILL BE READY TO INSTALL A TRANSMITTER IN THE NEXT
AVAILABLE SENSOR ZONE LOCATION. IF THE VB-4B VOICE BOARD IS
INSTALLED, THE CONSOLE WILL ANNOUNCE THE SENSOR ZONE LOCATION
NUMBER.
NOTE: WRITE DOWN EACH TRANSMITTER'S TYPE AND ZONE NUMBER
WHEN THE TRANSMITTER IS ADDED. THE CENTRAL STATION WILL NEED
TO KNOW THE TYPE AND REPORTING ZONE FOR EACH TRANSMITTER
THE CONSOLE WILL RETURN TO OPERATE
MODE AUTOMATICALLY AFTER 3 MINUTES
TURN POWER
SWITCH ON
ON
IF REQUIRED, CHANGE THE DIALING METHOD
BY PRESSING AND HOLDING THE HOME & CLEAR
BUTTONS WHILE SWITCHING THE POWER ON
• 7 BEEPS SOUND FOR PULSE DIALING
• 8 BEEPS SOUND FOR TONE DIALING
NOTE: THE DEFAULT DIALING METHOD IS TONE DIALING
ADDS ONE TRANSMITTER AT A TIME
PRESS CLEAR BUTTON
FOR 5 SECONDS
• 5 BEEPS SOUND
(TX ADD MODE)
1
2
ACTIVATE TRANSMITTER
• 1 BEEP SOUNDS
(TX ADDED)
CONSOLE REVERTS
TO OPERATE MODE
NOTE: IF THE CONSOLE'S MEMORY
IS FULL, ONE LONG BEEP SOUNDS WHEN
TRYING TO ADD A TRANSMITTER
3
REPEAT STEPS 1 & 2 FOR ADDITIONAL
TRANSMITTERS (UP TO 16 TOTAL)
NOTE: PRESS CLEAR BEFORE TRANSMITTING TO RETURN
TO OPERATE MODE WITHOUT ENTERING A TRANSMITTER
• 2 BEEPS SOUND WITH ACTIVITY TIMER ENABLED
• 3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED
THE CONSOLE WILL RETURN TO OPERATE MODE
AUTOMATICALLY AFTER 30 SECONDS
DXS-62A
NOTE: WRITE DOWN EACH TRANSMITTER'S TYPE AND ZONE NUMBER
WHEN THE TRANSMITTER IS ADDED. THE CENTRAL STATION WILL NEED