LG Electronics 47WX50MF Blood Glucose Meter User Manual


 
72
ENG
ENGLISH
CONTROLLING THE MULTIPLE PRODUCT
36. Reset (Command: f k)
ToexecutethePicture,Screen,AudioandFactory
resetfunction.
Transmission
[f][k][][SetID][][Data][Cr]
Data 00:PictureReset
01:ScreenReset
02:FactoryReset
03:AudioReset
Acknowledgement
[k][][SetID][][OK/NG][Data][x]
37. Tile Mode (Command: d d)
ToselectaTileModeOff/OnandTileRow/Column
size.
Transmission
[d][d][][SetID][][Data][Cr]
Data 00toFF:1stbyte-TileColumnvalue
2ndbyte-TileRowvalue
*00,01,10,11meansTileModeOff.
Acknowledgement
[d][][SetID][][OK/NG][Data][x]
38. Tile Mode Check (Command: d z)
TocheckTileModestatus.
Transmission
[d][z][][SetID][][Data][Cr]
Data FF:CheckTileModestatus
Acknowledgement
[z][][SetID][][OK/NG][Data1][Data2][Data3][x]
Data1 00:TileModeOff
01:TileModeOn
Data2 00to0F:TileColumeValue
Data3 00to0F:TileRowValue
39. Tile ID (Command: d i)
TosetTileID.
Transmission
[d][i][][SetID][][Data][x]
Data 01toE1: TileID01to225**
FF:ReadTileID
**Datacouldnotbesetover(TileRow)x(Tile
Column)
Acknowledgement
[i][][SetID][][OK/NG][Data][x]
*NGwillbereturnifdataisover(TileRow)x(Tile
Column),except0xFF.
40. Tile H Position (Command: d e)
TosettheTileHorizontalposition.
*OnlyavailablewhenTileNaturalModeisoff.
Transmission
[d][e][][SetID][][Data][Cr]
Data 00to32:Left(-50)toRight(0)
(*Left/RightvaluesdependonTileHsize.)
Acknowledgement
[e][][SetID][][OK/NG][Data][x]
41. Tile V Position (Command: d f)
TosettheTileVerticalposition.
*OnlyavailablewhenTileNaturalModeisoff.
Transmission
[d][f][][SetID][][Data][Cr]
Data 0to32:Bottom(0)toTop(50)
(*Bottom/TopvaluesdependonTileVsize.)
Acknowledgement
[f][][SetID][][OK/NG][Data][x]