Troubleshooting Procedures
This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified
electrician should correct all electrical problems. For warranty service, contact your dealer or wholesale
distributor.
Troubleshooting the Bath System
Symptoms Probable Causes Recommended Action
1. User keypad does not
illuminate when power
button is pressed or the
outer ring is rotated.
A. No power to control. A. Check wiring and connect power.
B. Ground-Fault Circuit-Interrupter
(GFCI) or Residual Current
Device (RCD) tripped.
B. Reset GFCI or RCD. If it trips
again, refer to Ground-Fault
Circuit-Interrupter (GFCI) or
Residual Current Device (RCD)
trips when unit is turned on.
C. Wiring harness from user
keypad to control is loose,
disconnected or damaged.
C. Check wiring for proper
connections. Replace the wiring
harness if necessary. Refer to your
installer or wholesale dealer.
D. User keypad does not work. D. Replace the user keypad. Refer to
your installer or wholesale dealer.
E. Control does not work. E. Replace the control. Refer to your
installer or wholesale dealer.
2. Ground-Fault
Circuit-Interrupter (GFCI)
or Residual Current
Device (RCD) trips when
unit is turned on.
A. Electrical harness is wet or
damaged.
A. Check for wet connections. Dry the
connections and repair the leak.
Check for insulation or connector
damage. Replace the harness if
damaged. Refer to your installer or
wholesale dealer.
B. Electrical wiring to the junction
box is wet or damaged.
B. Have a qualified electrician
diagnose and correct the problem
in accordance with applicable
building and electrical codes.
C. Electrical wiring to the power
cord is wet or damaged.
C. Have a qualified electrician
diagnose and correct the problem
in accordance with applicable
building and electrical codes.
D. Blower motor does not work. D. Replace the blower motor. Refer to
your installer or wholesale dealer.