Invacare XPO2 Oxygen Equipment User Manual


 
15
Invacare
®
Patient Monitoring Systems
Invacare
®
Patient Monitoring Systems
(A) IRC700 (B) IRC725 (C) IRC735 (D) IRC775 (E) IRC600
E
C DB
A
Patient Monitoring Systems Specifications
Digit
®
pulse oximeter Pulse oximeter Printing pulse oximeter Sleep printing pulse oximeter Digital pulse oximeter
E (IRC600) A (IRC700) B (IRC725) C (IRC735) D (IRC775)
Displays, indicators & keys
SpO
2
LED numeric display, LED numeric display, LED numeric display, LED numeric display, LED numeric display,
0.32" (8.1 mm) high 0.43" (10.9 mm) high 0.43" (10.9 mm) high 0.3" (7.62 mm) high 0.3" (7.62 mm) high
Pulse rate LED numeric display, LED numeric display, LED numeric display, LED numeric display, LED numeric display,
0.32" (8.1 mm) high 0.375" (9.5 mm) high 0.375" (9.5 mm) high 0.3" (7.62 mm) high 0.3" (7.62 mm) high
Pulse strength LED numeric display, logarithmically scaled logarithmically scaled logarithmically scaled logarithmically scaled
0.32" (8.1 mm) high 8-segment bar graph 8-segment bar graph 8-segment bar graph 8-segment bar graph
Alarm silence n/a n/a n/a LED flashes or lights to LED flashes or lights to
remind user that audio remind user that audio
alarms are disabled alarms are disabled
Low battery indicator flashes left bar indicator lights 1 segment LED lights LED flashes when LED flashes when
when 30 minutes when less than 2 hours approximately 30 min. approximately 30 min.
remain remain of battery life remains of battery life remains
Probe unit shuts down if unit is not connected, if unit is not connected, LED flashes to alert LED flashes to alert
after 8 seconds system shuts off system shuts off operator to check operator to check
when not in use in 2 minutes in 2 minutes SpO
2
probe placement SpO
2
probe placement
SpO
2
Range 0-99% 0-99% 0-99% 0-99% 0-99%
Accuracy ± 2% at 70%-99% ± 2% at 70%-100%; ± 2% at 70%-90% ± 2% at 70%-99% ± 2% at 70%-99%;
± 3% at 50%-69% ± 3% at 50%-69%
Averaging 8-pulse beat average 8-pulse beat average 8-pulse beat average 4-pulse beat average 4-, 8- or 16- pulse
beat average
Alarm range n/a n/a n/a n/a high – 50%-99%
and OFF (1% steps)
low – OFF and
50%-98% (1% steps)
Pulse rate
Range 30-254 bpm 30-254 bpm 30-254 bpm 30-254 bpm 30-254 bpm
Accuracy ± 2% ± 2% ± 2% ± 2% ± 2%
Averaging 8-second average 8-second average 8-second average 8-second average 8- or 16-second average
Alarm range n/a n/a n/a n/a high– 5-254 bpm
and OFF (1 bpm steps)
low– OFF and 5-254 bpm
(1 bpm steps)
Memory n/a 99 spot-checks 99 spot-checks 99 patients or 99 patients or
102 hours of run time 102 hours of run time
Dimensions 1.7" h x 2.25" w x 1.5" d 6.30" h x 3.25" w x 1.25" d 6.60" h x 2.75" w x 1.43" d 6.60" h x 2.75" w x 1.43" d 6.60" h x 2.75" w x 1.43" d
4.3cm x 5.7 cm x 3.8 cm 16.0 cm x 8.3 cm x 3.2 cm 16.8 cm x 7.0 cm x 3.6 cm 16.8 cm x 7.0 cm x 3.6 cm 16.8 cm x 7.0 cm x 3.6 cm
Weight 3 oz. (.09 kg) 16.5 oz. (0.5 kg) 13 oz. (0.4 kg) 13 oz. (0.4 kg) 16 oz. (0.5 kg)
with batteries with batteries with batteries with batteries with batteries
Auxiliary serial printer/computer output
n/a SpO
2
and pulse-rate SpO
2
and pulse-rate values n/a SpO
2
, pulse-rate and
values output every 5 output every 5 seconds pulse strength values
seconds to optional output every 5 seconds
to optional printer; spot-
check and graphic trends
of stored data
Power requirements
Power source 2 “AAA” cell alkaline 3 “C” cell alkaline 4 “AA” cell alkaline 4 “AA” cell alkaline 6 “AA”cell alkaline
batteries or NiCad
®
batteries batteries batteries batteries
Battery life approximately approximately 14 hours with continuous 2 overnight sleep 2 overnight sleep
1,400 spot-checks 1,500 spot-checks printing screening cycles screening cycles
Safety approvals UL & CSA listed UL & CSA listed UL & CSA listed UL & CSA listed UL and CSA listed
Limited warranty 1 year 2 years 2 years 2 years 2 years