Harmar Mobility CPL1400 Personal Lift User Manual


 
Installing the Outer Guard Panels
Step 1
Remove the hexbolts on the corners of the
platform. Insert the guard panel posts into
the pockets in the platform. The smooth side
of the guard panels should face in towards
the center of the platform.
If you have a 90 degree exit platform, install
the end guard panel using the provided
bracket and bolt to inner guard panel.
Step 2
Install the platform control box on the rear
guard panel using screws and nuts through
the panel.
Step 3
Plug in the harness for the platform control
box. Secure the harnesses under the clip on
top of the carriage flange.
Installing Fixed
Ramp
Step 1
• Position the ramp after the lift is in its final
location.
• Maintain a gap of 3/8” to 3/4” between the
ramp and platform.
• Drill a pilot hole into the concrete and
fasten using supplied concrete lags through
ramp flanges.
7