Graco 24T885 Thermometer User Manual


 
2 332653A
300 psi LPG Gas Gauge Installation for ThermoLazer
1. Close manual gas shutoff valve on propane tank,
then disconnect gas supply hose (99) from propane
tank.
2. Unscrew gas supply hose (99) from bulkhead fitting
(102).
3. Apply pipe sealant to tee fitting (11) and screw into
bulkhead fitting (102). Screw in until gas tight. Install
tee as shown.
4. Apply pipe sealant to bushing (6) and screw into tee
fitting (11). Screw in until gas tight. Position gauge
(1) as shown.
5. Apply pipe sealant to filter fitting (10) and screw into
tee fitting (11). Screw in until gas tight.
6. Apply pipe sealant to hose (99) and screw into filter
fitting (10). Screw in until gas tight.
7. Connect gas supply hose (99) to propane tank.
8. Open manual gas shutoff valve on propane.
9. Check gas line for gas leaks (see ThermoLazer
Operation Manual).
NOTICE
Tighten by turning bushing (6) and holding tee fitting
(11). Do NOT turn gauge (1). Damage to the gauge
will occur.
ti14128a
ti22097a
99
ti22105a
99
102
ti22101a
11
ti22100a
11
6
1
ti22098a
11
10
ti22099a
10
99
99
ti14411b
ti14127a