Graco 24B327 Sleep Apnea Machine User Manual


 
313537D 3
Operation
Spraying
1. Set material flow (see sprayer instruction manual for
additional information).
2. Spray test pattern
3. Turn air knob on and adjust, and/or select another
air nozzle, for desired pattern.
Note: Air continues to flow when handle is in off position
to keep material out of air passages.
Cleanup
Flush applicator after each work session before fluid
begins to cure in applicator. Remove check valve (15)
and clean all residue from air passages. Store in a dry
location. Do not leave the applicator or any parts in
water or cleaning solvents.
NOTE: Check valve (15) will be damaged if any object is
inserted into valve.
Spool Valve Repair
Before performing any maintenance on applicator, read
all warnings on front cover of this manual and relieve
pressure.
Spool Valve Removal
1. Remove screw (3d) and handle (8) from spool (3).
2. Remove retaining ring (3c) and bearing (3b).
3. Remove spool (3) from housing (1).
Spool Valve Installation
1. Apply grease (supplied with Kit 24B329) to spool,
o-rings and bearing and inside of housing.
2. Assemble o-rings onto spool.
3. Install spool in housing and bearing. Secure with
retaining ring (3c).
4. Install handle with screw.
Technical Data
WARNING
All sealing surfaces must be clean to prevent leaks
and damage to equipment.
Maximum fluid working pressure 1000 psi (6.9 MPa, 69 bar)
Maximum air working pressure 250 psi (1.7 MPa, 17 bar)
Air Requirements 30 scfm (0.84 m3/min) Maximum
Fluid Inlet Size 1 in.(m) cam and groove (Graco HP)
Air Inlet Size 1/4 npsm(m)
Wetted Parts Aluminum, stainless steel, PE, POM, polyurethane, nitrile, nylon, PVC, tungsten
carbide
Weight † 2.9 lb (1,3 kg)
Height 5.8 in. (14,7 cm)
Width 7.0 in. (17,8 cm)
Length † 12.7 in. (32,3 cm)
Sound Data without Air (applicator
only):
Sound Pressure Level 84dB(A)*
Sound Power Level 83dB(A)*
Sound Data with Air (applicator
only):
Sound Pressure Level 118dB(A)*
Sound Power Level 118dB(A)*
* Spraying simulated acoustical texture under typical conditions as specified by the material manufacturer.
† Airless configuration