Buzzaround Lite™ Owner’s Manual – Models GB106 and GB106XR Updated 07/08
Page 23
Possible causes for the main circuit breaker to trip
• “Run-down” batteries.
• Over exerting the motor.
Possible solutions:
• Recharge your batteries.
• If the problem persists, have an authorized Golden Technologies dealer
“load test” the batteries to assure they are not damaged.
• If the problem persists, assure your battery charger is operating properly.
Resetting the Main Circuit Breaker
If the main circuit breaker trips as a result of “run-down” batteries or because of a
temporary overload, reset the circuit breaker using the following directions:
1. Wait 5 minutes to allow the motor and electronics board to cool, or return
to “normal” operating temperature.
2. Press in on the main circuit breaker reset button.
WARNING: BE SURE YOU REMOVE THE KEY FROM THE KEY RECEPTACLE BEFORE
RESETTING YOUR SCOOTER.
NOTE: If the main circuit breaker continues to trip, there is an underlying
electrical fault that needs professional attention. Please contact your local
Golden Technologies Dealer.
NOTE: Do not reset your main circuit breaker repeatedly. You must correct the
underlying problem. Failure to correct the problem could cause injury or damage
and will void the warranty.