Excell Precision WEIGHING SCALES Scale User Manual


 
V1.1 ZSME300000011
24
EXCELL PRECISION CO., LTD.
(4) Power Source Illustration
The relay circuit board can be supplied either by the external AC power or internal DC
power.
Relay powered by external AC power
PIN4 and PIN5 are connected with AC power source; J1 and J2 OPEN
Relay powered by internal DC power
No power source input to PIN4 and PIN5; J1 and J2 SHORT
(5) Connection Setting
OK, High, Low can be set at NO (normal open status) or NC (normal close status)
respectively.
OKHighLow at NO ( normal open status) Þ default setting
OKHighLow at NC( normal close status)
Please use a knife to cut the J3, J4 and J5 not connect (open) and solder the J6, J7
and J8 connected.