Excell Precision Weighing Scale Scale User Manual


 
EXCELL PRECISION CO., LTD.
Dolphin 9903 V 1.1 SME300000041
14
Input the desired high limit value
Input the desired low limit value
Input the buzzer parameters
.
.
.
.
1-3 Check-Weighing Setting
4 If both the preset high limit and the low limit values are set as 0, the check-weighing
function is invalid.
ON/ZERO Upward digit selecting (0-9)
UNITS Downward digit selecting (9-0)
TARE Move the cursor rightward
NET/GROSS Move the cursor leftward
Press the
TARE
key
The
display shows the current
setting of high limit value
Press the
TARE
key
kg
The display shows the current
setting of low limit value
The display shows the current
setting of buzzer parameters
Press the
TARE
key
Buzzer parameter setting
(a) (b) (c)
(a) 1 the buzzer beeps to alarm
0 the buzzer does not beep
(b) 1 beep stable
0 beep unstable
(c) 1 beeps when the weight is
between high and low limit.
0 beeps when the weight is out
of high and low limit.
(Weight over 10d)
kg
kg
kg
Press the
TARE
key