Dymo PS2R1-P Scale User Manual


 
2. Press COUNT. Display will show “Ad 10”. Add 10 like pieces, weighing a minimum of 1 oz**. Display will
show “Pr. C”.
3. Press COUNT. Display will show “10”. Add desired like pieces to be counted.
4. Display will show total pieces counted. Remove pieces counted.
5. Press ZERO. Display will show “0.0” indicating ounce mode.
Note: If pieces to be counted require a container, place empty container on platform before following steps 1
through 5.
** If pieces to be counted do not total at least 1 oz, you must add additional pieces in multiples of 10 until 1 oz or more is attained (e.g. 10, 20, 30
pieces). In order to arrive at the correct quantity, you must multiply the final piece count shown in step 4 by the number of multiples of 10 pieces
used in step 2.
AUTOMATIC OFF: When powered by a battery, the scale will automatically turn off after approximately 30
seconds of inactivity (no weight change). This prolongs Battery life.
To deactivate Automatic Turn Off: While scale is off, PRESS and HOLD ZERO. While still holding ZERO
press ON until “SHOF” appears briefly in display. This feature is automatically deactivated when the scale is
powered by a 120V adapter.
To reactivate Automatic Turn Off: PRESS OFF to turn off scale. Press ON again to turn the scale back on
and Automatic Off will be activated.
OVERLOAD WARNING: appearing in the upper half of display indicates you have exceeded Scale
capacity.
LOW BATTERY WARNING: Blinking “ appearing on display indicates low battery.
RATE CHANGE INSTRUCTIONS
You have the option of changing Rates by purchasing and replacing the rate chip (visit our website
www.pelouze.com or contact us at 1-888-807-2253) or by programming the new rates into the scale
yourself. To program the new rates, follow this procedure:
1. Initiate Program Mode. With the scale turned off, Press
and Hold the A key (see diagram at right) and Press and
Hold ON at the same time. The display will show
“ then “2162” or the current version code,
“USPS” and finally the 1 oz 1
st
Class postage rate (the last
digit blinking).
IMPORTANT: If “Err6” or “0” appear, STOP! The wrong two
buttons have been pressed. Turn Scale Off. Begin again.
2. Enter New Rate from Right to Left. As each digit blinks,
Press and Hold the B key to change it. Press D to move
left to the next digit. When the new rate is completely
entered, Press the C key to store in memory.
3. Complete Rate Changes. Repeat step 2 to enter all 1
st
Class rate changes up to 16 oz (use Priority Mail
postage rates for 13 oz to 16 oz rates) and then all Express Mail rate changes up to 32 oz. When you
complete the 32 oz Express Mail postage rate, “ACCP” will appear on the display, verifying acceptance of
the new rates.
4. Press OFF to turn scale off. Scale is now ready to resume normal use.
CARE & CLEANING
Your PS2R1-P is a precision instrument, engineered to give years of valuable service. Care should be given
to maintain its accuracy and appearance. PROTECT YOUR SCALE FROM:
• Being Dropped • Extreme Temperatures
• Shock Loading • Liquid Spills
• Excessive weight • Other Abuses
This scale is easily cleaned by wiping with a damp, soft cloth and mild nonabrasive detergent.
SPECIFICATIONS
DIMENSIONS: 5" x 6
3
/4” x 2
1
/16" PLATFORM SIZE: 4
3
/4” x 4
1
/8"
CAPACITY: 32 oz./1000g x 0.1 oz/1 g. MODEL NO.: PS2R1-P
POWER SOURCE: 9V Battery or Pelouze ADPT2 Adapter with 120V AC 60Hz 3W input/ 9V DC 100mA
Output
NOT LEGAL FOR TRADE
- 3 -
AB