Citizen CH-453 Blood Pressure Monitor User Manual


 
- Eng 14 -
Deutsch
English
Español Português Italiano
Français
- Eng 15 -
English
EspañolPortuguêsDeutsch
Français
Italiano
4 is displayed soon after
pressurization is complete, and
measurement begins automatically.
* If the unit judges that pressurization
is insuf cient, it automatically
repressurizes.
5 blinks each time a pulse is
detected, and the pressure value
is displayed on the diastolic blood
pressure display.
6 Once measurement is complete, the
cuff de ates and the measurement
results (systolic/diastolic blood
pressure values, pulse) are displayed.
* Systolic/diastolic blood pressure
values (two seconds) and pulse (one
second) are displayed alternately.
* Provided there is no error in the measurement results, they are stored
automatically.
MEASURING YOUR BLOOD PRESSURE
Plug the air hose connector
rmly into the air hose
socket on the main unit, as
illustrated.
2 Plug the air hose
connector into the main
unit.
3 Place the cuff at the height of the heart.
4 Press the START/STOP switch (the blue switch).
* If the pressurization value exceeds 280 mmHg, if pressurization feels
abnormal, or if you want to stop the measurement process, press the
START/STOP switch again. The cuff de ates, and the power turns off.
1 All digits on the display blink for
approximately one second.
All digits displayed is an initial
display, indicating that the monitor is
functioning normal.
The
mark will also be displayed
but this does not indicate that the
battery needs to be replaced.
2 *
is displayed for approximately
one second.
3 The cuff is pressurized automatically.
Air hose connector
Air hose socket
MEASURING YOUR BLOOD PRESSURE
The Body Movement Indicator is displayed on the measurement
results display if you move your hand or arm during measurement,
causing a substantial pressure change to be detected.
• If the Body Movement Indicator is displayed, measure your blood
pressure again.
If an irregular heartbeat is detected during measurement, the
Irregular Heartbeat (IHB) Indicator is displayed after measurement
is completed.
An irregular heart beat is de ned as a heart beat that varies by
±25% from the middle of 5 heart beat intervals during the blood
pressure measurement.
• Measurement may not be correct if your heartbeat uctuates greatly
during measurement. If the Irregular Heartbeat (IHB) Indicator is
displayed, measure your blood pressure again.
Caution
If the Irregular Heartbeat (IHB) Indicator appears
frequently, you are advised to consult a doctor about
your health condition.