Chauvet GVC Wheelchair User Manual


 
Scorpion™ RVM/RGY/GVC User Manual (Rev. 01e) Page 7 of 24
Laser Emission Data
Laser light - Avoid direct eye contact!
Further guidelines and safety programs for safe use of lasers can be found in the ANSI
Z136.1 Standard “For Safe Use of Lasers”, available from the Laser Institute of America:
www.laserinstitute.org. Many local governments, corporations, agencies, military and others,
require all lasers to be used under the guidelines of ANSI Z136.1. Laser Display guidance
can be obtained via the International Laser Display Association: www.laserist.org.
Scorpion™ RVM
Laser Classification
Class IIIa (equivalent to US Class IIIa)
Red Laser Medium
650 nm, GaAIAs
Violet Laser Medium
405 nm, GaN
Beam Diameter
<15 mm
Pulse Data
All pulses < 4 Hz (>0.25 sec)
Divergence (each beam)
<2 mrad
Laser Power for Classification via 7 mm aperture
<5 mW
Scorpion™ GVC
Laser Classification
Class IIIa (equivalent to US Class IIIa)
Green Laser Medium
DPSS Nd: YVO4, 532 nm
Violet Laser Medium
405 nm, GaN
Beam Diameter
<5 mm at aperture
Pulse Data
All pulses < 4 Hz (>0.25 sec)
Divergence (each beam)
<2 mrad
Laser Power for Classification via 7 mm aperture
<5 mW
Scorpion™ RGY
Laser Classification
Class IIIa (equivalent to US Class IIIa)
Red Laser Medium
650 nm, GaAIAs
Green Laser Medium
532 nm, DPSS Nd: YV04
Beam Diameter
<15 mm
Pulse Data
All pulses < 4 Hz (>0.25 sec)
Divergence (each beam)
<2 mrad
Laser Power for Classification via 7 mm aperture
<5 mW
*As measured under IEC measurement conditions for classification.
Laser Compliance Statement
This laser product complies with Laser Safety Standards under US FDA/CDRH, per 21 CFR
1010 & 1040. This laser device is Classified IIIa. (Class 3R is the international equivalent of
US Class IIIa). No maintenance is required to keep this product in compliance with laser
performance standards.
LASER EXPOSURE WARNING