A&D HC-3Ki Scale User Manual


 
34
010
Auto power-off
0
Auto power-off disabled.
1
Auto power-off enabled.
f-04-06” is for factory use and should be “0”.
F-05-X Comparator
Comparator Mode.
0
Comparator OFF.
1
Compare all data.
2
Compare stable data.
3
Compare all data except when near ZERO*.
4
Compare stable data except when near ZERO*.
5
Compare all positive data except when near ZERO*
6
Compare stable positive data except when near ZERO*.
* “near ZERO” means between –4d and +4d of weight data.
Data to Compare – Count or Weight
0
Compare count data.
1
Compare weight data.
Upper Limit.
0
Enter via the 10-key pad.
Use the . key to “set minus value.
Lower Limit.
0
Enter via the 10-key pad.
Use the . key to set minus value.
A Beeper With Comparator Results.
These are beeps for the comparator, not for the key
operation.
000
All Comparator Beepers are OFF.
Example:
The OK beep sounds – HI & LO doesn't
sound. The scale will beep continuously
when display meets OK condition.
f-05-01
f-05-02
f-04-05
f-05-05
000
0
= Beeper OFF
1 = Beeper ON
HI LO
OK
f-05-03
f-05-04