FIT TESTING
Note: Fit testing is a U.S. OSHA and Canadian CSA Z94.4 standard requirement. Therefore,
either quantitative or qualitative fit testing must be conducted prior to the respirator being issued.
Quantitative Fit Testing (QNFT) can be conducted using a 3M
TM
Fit Test Adapter 601
and 42 CFR 84 P100 filters such as the 3M
TM
P100 Particulate Filters 2091 or 7093.
Qualitative Fit Testing (QLFT) with the 3M
TM
Qualitative Fit Test
Apparatus FT-10 or FT-30 can be conducted using any of the NIOSH approved 42 CFR 84 Particulate
filters.
Note: For further information concerning fit testing, contact 3M OH&ESD Technical Service at
1-800-243-4630 or a 3M location in your region. In Canada call Technical Service at 1-800-267-4414.
To conduct QNFT with round retainer type filters, the 3M
TM
Fit Test Adapter 7930 is needed.
INSPECTION, CLEANING AND STORAGE
Inspection Procedure
This respirator must be inspected before each use to ensure it is in good operating condition. Any
damaged or defective parts must be replaced before use. The following procedure can be used as a
guideline.