A SERVICE OF

logo

OPERATING MODES
Mode Selection: By front panel rotary switch.
Mode A: Independent outputs each capable of 0-75V at 0-2A.
Mode B:
Output 2 only active, 0-75V at 0-4A.
Output 1 disabled.
Mode C: Output 2 only active, 0-150V at 0-2A.
Output 1 disabled.
METER SPECIFICATIONS
Meter Types: Dual 3 digit meters with 14mm (0.56") LEDs. Reading rate 4 Hz.
Meter Resolutions: 100mV, 10mA
Meter Accuracies: Voltage 0.3% of reading ± 1 digit,
Current 0.6% of reading ± 1 digit
Operating Modes: Output 1 meters are blanked in Modes B and C.
GENERAL
AC Input: 110V-240V AC ±10%, 50/60Hz. Installation Category II.
Power Consumption: 500VA max.
Operating Range: +5ºC to +40ºC, 20% to 80% RH.
Storage Range:
40ºC to + 70ºC.
Environmental: Indoor use at altitudes up to 2000m, Pollution Degree 2.
Safety: Complies with EN61010-1.
EMC: Complies with EN61326.
Size: 260 x 160 x 320mm (WxHxD).
Weight: 4.3kg
4