13. Set all timer dials to 5 minutes. (Turn timer knob to 10 minutes or more to trip the switches,
then back to 5 minutes.)
14. Press the top of the compartment switch (Fig. 6 or 7) to start
the timer. Steam will be heard entering the compartments.
15. When timer dials are at 1 minute, steam flow to the
compartments stops and the compartment drain opens. The
cold water condenser in the drain may cycle on.
16. When the timers reach 0, silence the buzzers by pressing the
bottom of the compartment switch.
17. Open compartment doors. Verify that the compartments
were heated and drained
.
18. Press [ O ] on the power switch on the boiler to turn the
steamer off. The boiler will automatically blow down.
COMPARTMENT
OPERATION
R
EFER TO PAGE 20 – 21 FOR
AUTOMATIC
CONTROLS.