Procedure
Pressthepiping/wiringcorrectionswitch(SW871)1minuteormoreafter
turningonthepowersupply.
• Correction completes in 10 to 15 minutes. When the correction is com
-
pleted,itsresult
isshownbyLEDindication.Detailsaredescribedin
the following table.
• To cancel this function during its operation, press the piping/wiring cor-
rectionswitch
(SW871)again.
• When the correction completed without error, do not press the piping/
wiringcorrectionswitch(SW871)again.
When the result was “cannot be corrected”, press the piping/wiring cor
-
rectionswitch
(SW871)againtocancelthisfunction.Then,conrmthe
wiringandpipingcombinationinaconventionalmannerbyoperatingthe
indoorunitsonebyone.
• The operation is done while the power is supplied. Make sure not to
contactpartsotherthantheswitch,includingtheP.C.board.Thismay
causeelectricshockorburnbyhotpartsandlivepartsaroundthe
switch.ContactingthelivepartsmaycauseP.C.boarddamage.
• To prevent electronic control P.C. board damage, make sure to per
-
form static
elimination before operating this function.
• This function does not operate when the outside temperature is 0°C
(32°F)orbelow.
4-4. EXPLANATION TO THE USER
• Using the OPERATING INSTRUCTIONS, explain to the user how to
use the air conditioner (how to use the remote controller, how to re-
movetheair
lters,howtoremoveorputtheremotecontrollerinthe
remotecontrollerholder,howtoclean,precautionsforoperation,etc.)
• Recommend the user to read the OPERATING INSTRUCTIONS care-
fully.
LED indication during detection:
LED
1(Red) 2(Yellow) 3(Green)
Lighted Lighted Blinking
Result of piping/wiring correction function
LED
Result
1(Red)
2(Yellow) 3(Green)
Lighted Not lighted
Lighted Completed(Correctedsuccessfully)
Blinking Blinking Blinking Cannot be
corrected
Other indications
Refer to “SAFETY PRECAUTIONS
WHEN LED FLASHES” located
behind the service panel.
4-3. TEST RUN
• Be sure to perform the test run for each unit. Make sure each indoor
unitoperatesproperlyfollowingtheinstallationmanualattachedtothe
unit.
• Ifyou
performthetestrunforallindoorunitsatonce,youcannotde-
tectanyerroneous
connection,ifany,oftherefrigerantpipesandthe
indoor/outdoor unit connecting wires.
About the restart protective mechanism
Onc
e the compressor stops, the restart preventive device operates so the
compressor will not operate for 3 minutes to protect the air conditioner.
Wiring/piping correction function
This unit
has a wiring/piping correction function which corrects wiring
andpipingcombination.Whenthereispossibilityofincorrectwiringand
pipingcombination,andconrmingthecombinationisdifcult,usethis
functiontodetectandcorrectthecombinationbyfollowingtheproce
-
dures below
.
Make sure that the following is done.
• Power is supplied to the unit.
• Stop valves are open.
Note:
Duringdetection,theoperationoftheindoorunitiscontrolledbytheout-
doorunit.
Duringdetection,theindoorunitautomaticallystopsoperation.
This is not a malfunction.
SG79Y871H02.indb 9 9/7/2007 1:09:45 PM