A SERVICE OF

logo

Chapter 9 Maintenance and Troubleshooting
120
9-3 Alarms
a) With respect to setting of basic menu item 016
During reception of commands from an external device connected to the REMOTE connector
Non AV Full off An attempt was made to record, display
an E-E picture, record an essence mark,
or add a quick scene selection sub clip
when there was no free Non-Real-Time
space.
Insert a different disc with enough free
capacity.
Message in time
data display
Display
condition
a)
Description Action
Message in time
data display
Display
condition
a)
Description Action
No Disc! on A recording, playback, search, or other
command was received with no disc
loaded.
Try the operation again after loading a disc.
REC INHI.! on A recording, E-E display, or edit preset
command was received for a write-
protected disc.
Try the operation again after setting the
write-protect tab to the recording enabled
position.
REC INHI.! on A recording, E-E display, or edit preset
command was received with extended
menu item 310 “REC INHIBIT” set to
“on.”
Try the operation again after setting
extended menu item 310 to “off.”
See 8-3-2 “Extended Menu Operations”
(page 102) about how to make this setting.
IMX50 Clip
IMX40 Clip
IMX30 Clip
DVCAM Clip
4CHx24 Clip
8CHx16 Clip
limit A recording, E-E display, or edit preset
command was received with basic menu
item for a disc recorded in a format
different from the specification of basic
menu item 031 “RECORDING
FORMAT.”
Try the operation again after changing the
setting of basic menu item 031.
See 8-2-2 “Basic Menu Operations” (page
88) about how to change this setting.
Run Salvage limit A recording, E-E display, or edit preset
command was received for a disc that
needs clip recovery (salvage).
Try the operation again after recovering
clips from the disc (salvage function).
See 3-5-7 “Handling of Discs When
Recording Does Not End Normally
(Salvage Function)” (page 47).
i.LINK! limit An edit preset command was received
with an input signal from the S400
(i.LINK) connector selected.
To perform this operation, use the VIDEO
INPUT SEL button to select a signal other
than “i.LINK.”
MAX # Files off The number of files on the disc had
reached the upper limit (5000), or there
was not enough capacity in the General
directory when a command was
received to record, display an E-E
picture, record an essence mark, or add
a quick scene selection sub clip.
Exchange the disc for one with enough
free capacity.
Disc Full! off A command was received to record or
display an E-E picture when there was
not enough free capacity on the disc, or
when the number of recorded clips had
reached the upper limit (300).
MAX# SB CLP off A command was received to add a sub
clip when the number of registered sub
clips had already reached the upper limit
(300) of the specifications of this unit.
These operations are not possible.
CL OVER DUR off A command was received to add a sub
clip when the total duration of sub clips
in the clip list had already reached the
upper limit (24 hours) of the
specifications of this unit.