![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/ee/dee9e6b3-ff35-4098-bc7b-ade710ead231/dee9e6b3-ff35-4098-bc7b-ade710ead231-bg50.png)
3-4
DXC-D30WS/P(E)/V1
3-2. BEFORE ADJUSTMENT
Note: 1. Before adjustment, connect the equipments
referring to “3-1-2. Connection”.
2. Before adjustment, Turn on POWER switch
and allow for 10-minute warm-up time.
3-2-1. Color Bar Signal Confirmation
Equipment: Vectorscope, Waveform monitor
Preparation: OUTPUT/DL/DCC+ switch/camera side
→ BARS
Test point: VIDEO OUT connector/camera side
Specification:
[for NTSC] [for PAL]
R
M
G
B
C
Y
G
Y
L
R
M
G
C
Y
G
Y
L
B
Burst Spot 75%Burst Spot 75%
3-2-2. Sensitivity Measurement Confirmation
Object: Overall white
Light: 3200K, 2000 lux
(If the pattern box is used, set the AUTO
mode)
Preparation:
• Adjust the zoom control at “TELE” so that the white
pattern frame matches the underscanned picture frame on
the screen.
• Lens iris → F11
• OUTPUT/DL/DCC+ switch/camera side → CAM
• WHITE BAL switch/camera side → PRESET
Equipment: Waveform monitor
Specification: 100 ±10 IRE (for NTSC)
700 ±70 mV (for PAL)
[for NTSC] [for PAL]
Note: If the specification is not met, perform “3-3-11.
CCD OUT Level Adjustment”.
• Chroma Level
Confirm that the beam spots of each color (R, YL, G,
CY, G, B and MG) are inside the “4” mark.
[for NTSC] [for PAL]
Note: • Partial difference between scale and signal
level is caused by photographic error.
• If the specifications are not met, carry out
from “3-3-2. INT SC Phase Adjustment”
through “3-3-9. Chroma (YC) Level
Adjustment”.