Digital Access Keypad Manual
SECO-LARM U.S.A., Inc.
Digital Access Keypad Manual
Cathode
12~24V
AC/DC
power
supply
+
--
Electric
Lock
N.O.
+
--
N.C.
N.O.
OR
N.O.
----------------
------------
--------
--------
ST-UV12-S1.0Q
1N4004
Output Relay
N.O. Output for
Fail-secure lock
N.C. Output for
Fail-safe lock
Egress button
(Inside premises)
Additional egress
buttons can be
connected in parallel
(+) (--)
12-24V AC/DC
Output #1
N.C. COM N.O.
Output #2
N.C. COM N.O.
Egress
In
Keypad
Active
Duress
Output
(--)
Ground
Door
Sensor
Interlock
Tamper
N.C.
O/P 1
Inhibit
CONNECTIONING INHIBIT
AUTHORIZATION CONTROL
WARNING
• For safety, ensure that no
one is inside the premises
before starting the door
lock inhibit function.
During inhibit, doors
remain locked.
• Connect a 1N4004 diode as close as possible to and in parallel with the DC-powered electromagnetic or electric lock.
This absorbs possible electromagnetic interference to prevent operation of the lock from damaging the keypad. A
1N4004 is not required for AC-powered locks.
• Connect the ground (-) terminal of the keypad to earth to prevent electrostatic discharge from damaging the keypad.
• The connection of relay output #1 disable to output #2, as shown above is optional. When so wired, output #2 is the
inhibit control. To use, program output #2 for shunt on/off operation. When output #2 is ON, relay output #1 will not
work. For example, this can be used to prevent users from entering the protected premises during the evening or
weekend. See programming option 61.
• The green LED lights while relay output #1 is activated to activate the lock.
• The red LED lights to show that relay output #1 is disabled by the activation of output #2.
• Tape all unused wires to prevent short circuits.
WARNING:
• If the inhibit control is used, all personnel must exit the protected premises before output #2 is activated. Otherwise,
personnel in the protected premises will not be able to exit until output #2 is turned OFF.
• The user code for output #2 in this case should be given only to personnel authorized to enter the premises any time.
It should not be given to other users.
TAMPER N.C.
ALARM
CONTROL
PANEL
24-hour N.O.
protection zone,
max. 100mA
DURESS OUTPUT
KEY ACTIVE or ALARM OUTPUT
1.5k
LED
Low
power
piezo
buzzer
+12V
Isolation
relay
+12V
N.O. relay
contact
MAGNETIC
DOOR
CONTACT
(N.C.)
DOOR SENSING
Required for:
• Door Auto Relock
• Door Forced-open Alarm
• Door Propped-open Alarm
• Mantrap (Interlock) Control
The Key Active Output will switch to ground
(-) for 10 seconds whenever a key is
touched. Use to turn ON an LED and/or a
small buzzer to notify a guard, or to energize
a relay to switch ON lights or CCTV camera.
Only one connection option is recommended.
Make sure the current sink does not exceed
the maximum rating of 100mA.
An external power supply and isolation relay
are necessary to drive high power devices
such as lights or CCTV cameras.
RELAY OUTPUT #2
--
Example, to shunt an alarm N.C. zone
Use Normally Open (N.O.) output
remove to shunt a Normally Closed
(N.C.) protection zone of an alarm
system.
Set relay output #2 to Start / Stop mode
(programming option 51)
N.C.
N.C. magnetic contact
To protection zone of an
alarm control panel
OR
WIRING:
Auxiliary Accessories
SM-200
SM-200
Note: If inhibit control
is activated, the duress
output is disabled.
ALARM
CONTROL
PANEL
24-hour N.C.
protection
zone
WIRING:
Example Wiring, with Inhibit Control Authorized
Page 6 Page 11
Tamper
N.C.
Duress
Output
(
-
)
Ground
Door
Sensing
Keypad
Active
Keypad
Active
Output #2
N.C. COM N.O.
(
-
)
Ground