Remote Control Functions
Setting data
Item
code
Item
No. Description
0000 No forced operation
0001 Forced operation for 1 minute
Automatic drain pump
operation
0060 Continuous operation
0000 None
Ventilation fan operation
0001 Ventilation fan operated by remote controller.
0000 Not used. (Body sensor is used.)
Wired remote controller sensor
0001 Remote control sensor is used.
0000 Normal (displayed)
“ Operation change control in
progress ” display
0001 Not displayed
0000 None
OFF reminder function for
when weekly timer is used
RAP valve
Discharge temperature control
0001 Only stop time setting is enabled.
0013
0000 Discharge temperature control OFF
0001 Discharge temperature control ON
0000 RAP valve control OFF
0001 RAP valve control ON
0014
0025
Heat exchanger temperature
for cold air discharge
(Heat exchanger control point
for control to prevent cold air)
0026
0000
Output linked with fan. (ON when indoor unit fan is
operating.)
Fan output switching
0001 Fan mode operation output
0000 No delayed start
0001 1 sec. delayed start
0002 2 sec. delayed start
0058 58 sec. delayed start
0059 59 sec. delayed start
Drain pump delayed start time
0060 60 sec. delayed start
0000 Humidifier output OFF. Drain pump stopped.
0001 Humidifier output ON. Drain pump operates.
0002
Humidifier output ON. Drain pump operates for 1 minute
when total humidifier operating time reaches 60 minutes.
Humidifier setting
0003 Humidifier output ON. Drain pump stopped.
0000 Standard setting
Flap operation mode
0001
Draft reduction mode (Flap lower-limit position is shifted
upwards.)
0000
Smudging reduction mode (Flap swing upper-limit position
is shifted downwards.)
0001 Normal mode
Flap swing mode
0002
Draft reduction mode (Flap swing lower-limit position is
shifted upwards.)
Control temperature 55°F (13°C )
Control temperature 57°F (14°C )
Control temperature 77°F (25°C )
Control temperature 78°F (26°C )
3. Timer Remote Controller (RCS-TM80BG)