SAMSUNG Installation
DCS-816 March 1999
7-3
7.3 Common Bell (Figure 7-3)
A customer-provided loud ringing device can be controlled by the general-purpose dry contact of
the DCS-816 system by means of the relevant program (MMC). Note that the dry contact is rated
24VDC, 1 Amp. The system requires MDF connection for the dry contact and the connection can
be made through the champ connector. See Figure 2-3 and refer to section 2.5 (MDF Cabling).
Using one pair twisted wires, connect a customer-provided loud bell to the general-purpose dry
contact via the champ connector on the base board.
CONNECTING AN EXTERNAL LOUD BELL
25 PAIR CABLE WITH FEMALE CONNECTOR TO THE BASE CHAMP CONNECTOR
CHAMP CONNECTION
PIN COLOUR CIRCUITS/ FUNCTIONS
² NO POLARITY
² CONNECT AN EXTERNAL LOUD BELL TO THE
INTERFACE VIA MDF
² THE CONTACT IS RATED 24VDC- 1A
36/11BK-GR/ GR-BK T/R, GP Dry Contact