![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/fb/1fb0d8d4-9068-4415-9362-f12406c276bc/1fb0d8d4-9068-4415-9362-f12406c276bc-bg3.png)
Manual-3
CP 64S REAR PANEL
1 PAGING INPUT Euroblock connectors may be operated balanced or unbalanced. See CP 64S Connections on page Manual-3.
2 PAGE 1 and PAGE 2 INPUT MIC / LINE switches select 30 dB Input Pads when set to LINE. Phantom Power (if enabled) is
disabled when LINE is selected. See page Manual-4 to internally set Phantom Power.
PAGE 1 and PAGE 2 INPUT TRIM controls adjust Page Input preamplifier gain to match the microphone/source in use, not to
set the page level in the Zones. e range is 30 dB to 60 dB.
PAGING INPUTS OL indicator lights when either of the Page Input preamplifiers comes within 3 dB of clipping, assisting the
setting of these trims.
3 Four PROGRAM INPUTS are provided. ree are non-priority Inputs. e fourth is a Program PRIORITY Input. When signal
is present at the PRIORITY Input, it is automatically selected as the Input source in the Zone(s) it is assigned with the Program
PRIORITY ASSIGN ZONE switch.
4 PRIORITY ASSIGN ZONE switch determines in which Zone(s) the automatic priority override is enabled. Off (none), Zone 1,
Zone 2 or Both are the possible settings. If you do not intend to use the Priority Input as an automatic override Input, do not assign
it with this switch. Use the Zone PROGRAM SELECT switch on the front panel.
5 LIMITER threshold controls set the maximum output level for each Zone. ese circuits are true voltage limiters with a ratio of
15:1. e threshold range is -20 dBu to +20 dBu.
6 OUTPUTS feature balanced cross-coupled line drivers with a Euroblock connector for each Zone. Zone 1 is stereo. Zone 2 is
mono, and both Expand outputs are mono. When operating cross-coupled line drivers unbalanced, it is essential to ground the (–)
pin. See CP 64S Connections on page Manual-3.
7 ZONE EXPAND OUT switches assign Page-only, Program-only or Zone 1 or Zone 2 as the source for each Expand Output.
8 DETECT THRESHOLD sets the Paging input signal level required to gate a Page on and light the front panel ACTIVE
indicator. e range is -∞ (on) to +4 dBu.
9 REMOTE PAGE ZONE ASSIGN port provides the interface for the PR 2 wired remote. e PR 2 remote is used for Zone as-
signment of Page Inputs. Follow the wiring as described on page Manual-5.
0 REMOTES ports provides the wiring interface for two optional ZR 1 wired remotes. Each ZR 1 remote provides remote control
of Zone Level and Zone Program Select functions. Follow the wiring as described on page Manual-5.
q Universal Voltage Input: via a miniature IEC 60320 C6 appliance inlet. is mates with an IEC 60320 C5 line cord (USA
domestic). Do not lift the ground connection!
q 0 6 1947 285 3
PRIORITY
ASSIGN
ZONE
ZONE
1
PAGE
+30 +60
1&2
PRIORITY
3 2 1
RANE CORP. MADE IN U.S.A.
OL
Z2 Z1
Z1 Z2
+ –+ –+ – + –
D1 D0
Vr Vc
Vr Vc
1
2
DETECT THRESHOLD
REMOTE PAGE
ZONE ASSIGN WIRING
PAGE 2 PAGE 1
LIMITERWIRING
ZONE 1 ZONE 2
PAGE
1
TRIM
PAGE
2
TRIM
CP 64S
+8
+8
PAGING INPUTS
R
L
R
L
+30 +60
MIC LINE
–20 +20–20 +20
REMOTES
OUTPUTS
MIN MAX
PROGRAM INPUTS
ZONE
2
EXPAND OUT
ZONE
1
EXPAND OUT
ZONE
2
Z2
PGM
Z2
EXPAND
Z2
MONO REMOTE
1
INPUT
1
REMOTE
2
INPUT
2Z1
RIGHT
Z1
EXPAND
Z1
LEFT
Z2
LEVEL
Z1
PGM
Z1
LEVEL
ACN 001 345 482
MIC LINE
100-240 V
50/60 Hz 12 WATTS
COMMERCIAL AUDIO
EQUIPMENT 24TJ
R
PGM PGM
PAGE
THIS DEVICE COMPLIES WITH
PART 15 OF THE FCC RULES FOR
A CLASS 'B' COMPUTING DEVICE.
off