Fireplace Size Requirements
A. Minimum Fireplace Opening
Minimum replace opening requirements are shown in
Figure 3.1.
• The rebrick (refractory), glass doors, screen rails,
screen mesh and log grates can be removed from a
factory built rebox in order to gain minimum gas insert
opening requirements.
• Any smoke shelves, shields, baf es and the metal oor
of the unit may be removed from a factory built rebox if
attached with mechanical fasteners. If the appliance is
placed on the base of the outer wrap, a ¼ inch airspace
must be provided between the insert and the oor of the
outer wrap.
Cutting of any sheet metal parts of the replace in which
the gas replace insert is to be installed is prohibited.
Figure 3.1 Fireplace Opening
NOTE: For actual appliance dimensions refer to Section 15.
20-3/8 in.
14-7/16 in.
29-3/4 in.
15 in.
5-9/16 in.
1-1/16 in.
18-15/16 in.
GAS INLET
(GAS BALL VALVE NOT SHOWN)
Fire Risk
Provide adequate clearance:
Around air openings
• To combustibles
For service access
Locate appliance away from traf c areas.
WARNING
EXISTING MINIMUM WOODBURNING FIREPLACE SIZE
Location Inches Millimeters
A Front Width 30-7/8 784
B Rear Width 25-5/8 651
C Depth 15 381
D Height 19-1/2 495
* NOTE: If exhaust collar on insert and replace damper do not line up, add 4 inches (102 mm) to minimum
replace height for bends in vent pipe.