- 11 -
Voltaje
Protector termal
Extensión de cordón
Herramientas
120 V c.a. (60 Hz)
Si 10.6 m (35pi) Si
Power Thermal Protector Cord Length Tools
120V AC (60 Hz)
Yes 10.6 m (35Ft.) Yes
Alimentation
Protecteur thermique
Longueur du cordon Accessoires
120 V c.a. (60 Hz)
Oui 10.6 m (35 pi) Oui
FEATURE CHART
Diagrama de características
Tableau des caractéristiques
- 38 -
The body hose located on the back of
the vacuum cleaner carries the dirt from
the nozzle up to the dust bag. If the
hose should become clogged:
➢➢
Unplug vacuum cleaner.
➢➢
Pull open suction inlet cover and
check for clogging. Secure suction
inlet cover properly after checking.
➢➢
Disconnect body hose from wand
holder and check hose ends.
➢➢
Plug in vacuum cleaner and turn on.
➢➢
Stretch body hose in and out to
remove clogs that may not be seen.
➢➢
If clog still exists, turn vacuum
cleaner OFF and UNPLUG PO
WER
CORD.
➢➢
Remove lower plate. See: “Removing
and Installing Lower Plate”
➢➢
Inspect inlet of nozzle hose and clear
any obstructions.