Terminal Position
POSITION MINIMUM SPACING mm
A Directly below an openable window, air vent, or any other ventilation opening 300
B Below gutters, soil pipes or drainpipes 75
C Below Eaves 100
D Below a Balcony 100
E From vertical drainpipes or soilpipes 75
F From internal or external corners 100
G Above adjacent ground or balcony level 100
H From a surface facing the terminal 600
I Facing another terminal 1,200
J From opening (door/window) in carport into dwelling 1,200
K Vertically from a terminal on the same wall 300
L Horizontally from a terminal on the same wall 300
N Below carport 600
A Quinnel Barrat and Quinnel guard (part. No. C2) should be screwed to the wall centrally over the terminal, when
the terminal height is less than 2 m from floor level.
Fig. 12
CLEARANCES:
* 600mm minimum clearance for servicing
access
460 5 min.5 min.
100 min.860200 min.
270 50 mm
600* min.
720