P/N 988552
LOW LEVEL MICROSWITCH KIT
INSTALLATION INSTRUCTIONS
1) Remove Trip Indicator Plug from Pump Stop Install the
Switch Bracket (in position shown) on Pump Stop and
secure by reinstalling Trip Indicator Plug.
2) Using the two mounting screws, washers and nuts,
assemble the 69360 Limit Switch (in up position as
shown) to Switch Bracket loosely.
3) Adjust Limit Switch to provide a .050" clearance
between Limit Switch Plunger and Trip Indicator Pin
(with pin in “Run” position). Tighten mounting screws
securely to hold switch in place.