Diagnostic Information 2-3
4402-001
Symptom Tables
Locate the symptom in the following tables and take the appropriate
action.
Carrier Transport Problems
Maintenance Station Problems
Operator Panel Problems
Symptom Action
No carrier movement
Slow carrier movement
Carrier stops
Carrier slams side frame
Go to the Carrier Transport
Service Check on page 2-6.
Symptom Action
Maintenance station:
Fails to cap the printheads
Fails to clean the printheads
Go to the Maintenance Station
Service Check on page 2-10.
Symptom Action
Buttons do not work
Power or status lights do not
work
Check operator panel cable
connection at J6 on the system
board. Then run the Power-On Self
Test (POST) Sequence on
page 2-1. If operator panel fails,
replace the operator panel assembly.
If the problem still exists, replace the
system board. Go to the System
Board Removal on page 4-12.
Note: If any buttons or lights fail,
check connection J6. If the problem
remains, replace the operator panel
assembly. Go to the Operator
Panel Removal on page 4-4.