4.7.6 DEFLECTION CIRCUIT ADJUSTMENTS
The setting (adjustment) using the remote control unit is made on the basis of the initial setting values.
The setting values which adjust the screen to the optimum condition can be different from the initial setting values.
When performing deflection circuit adjustment, adjusts PAL signal (fv: 50 Hz) in 4:3 mode and 16:9 mode respectively, and adjust
the NTSC signal (fv: 60 Hz) similarly.
Note:
Proceed to the following adjustment after having completed the adjustments of SUB BRIGHT and SUB PICTURE.
4. DEF
NOTE: The value with an asterisk * is variable for adjustment. The values in parenthesis ( ) are fixed values.
COMPRESS: OFF (4:3)
Adjustment item
Variable range Initial setting value
4:3
50Hz
Others
4:3 COMPRESS (16:9)
50Hz 60Hz 50Hz 60Hz
1. V-SHIFT 0 ~ 63 -32 ~ +31 0* 0* 0* 0*
2. V-SLOPE 0 ~ 63 -32 ~ +31 0* 0* 0* 0*
3. V-SIZE 0 ~ 63 -32 ~ +31 +15* 0* -4* -2*
4. H-CENT 0 ~ 63 -32 ~ +31 +35* 0* 0* 0*
5. H-SIZE 0 ~ 63 -32 ~ +31 +45* 0* 0* 0*
6. TRAPEZ 0 ~ 63 -32 ~ +31 0* 0* 0* 0*
7. EW-PIN 0 ~ 63 -32 ~ +31 -12* 0* 0* 0*
8. COR-UP 0 ~ 63 -32 ~ +31 0* 0* 0* 0*
9. COR-LO 0 ~ 63 -32 ~ +31 0* 0* 0* 0*
10. ANGLE 0 ~ 63 -32 ~ +31 0* 0* 0* 0*
11. BOW 0 ~ 63 -32 ~ +31 0* 0* 0* 0*
12. V-S.CR 0 ~ 63 -32 ~ +31 0* 0* 0* 0*
13. V-LIN 0 ~ 63 -32 ~ +31 0* 0* 0* 0*
14. V-ZOOM 0 ~ 63 -32 ~ +31 (+25) 0 -23* +3*
15. V-SCROLL 0 ~ 63 -32 ~ +31 (+32) (0) (0) (0)
Item
Measuring
instrument
Test point Adjustment part Description
V. SLOPE
adjustment
Signal
generator
Remote
control unit
[4. DEF]
2. V-SLOPE
- PAL V. SLOPE -
(1) Receive a PAL circle pattern signal of vertical
frequency 50Hz.
(2) Select 4. DEF from the SERVICE MENU.
(3) Select 2. V-SLOPE.
(4) Set the initial setting value of 2. V-SLOPE.
(5) Adjust 2. V-SLOPE to make "A = B".
(6) Press the [DISPLAY] key twice to return to
SERVICE MENU screen.
- NTSC V. SLOPE -
(1) Receive a NTSC circle pattern signal of vertical
frequency 60Hz.
(2) Make similar adjustment of NTSC V-SLOPE in the
same way as for "PAL V-SLOPE".
V. POSITION
adjustment
Signal
generator
Remote
control unit
[4. DEF]
1. V-SHIFT
- PAL V. POSITION -
(1) Receive a PAL circle pattern signal of vertical
frequency 50Hz.
(2) Select 1. V-SHIFT.
(3) Set the initial setting value of 1. V-SHIFT.
(4) Adjust 1. V-SHIFT to make "A = B".
- NTSC V. POSITION -
(1) Receive a NTSC circle pattern signal of vertical
frequency 60Hz.
(2) Make similar adjustment of NTSC V. POSITION in
the same way as for "PAL V. POSITION".
B
A
Blanking
line