STEP 4. WIRE WALLPLATE TERMINALS
IMPORTANT
All wiring must comply with local codes and ordinances. If
unsure about household wiring procedures, call your local
heating/air-conditioning contractor.
Refer to the labels
ou placed on the wires when
ou removed the
old thermostat (see illustration).
❑ Match the letter of
our old thermostat wire with the correspondin
terminal letter on
our new thermostat. Refer to Table 2.
❑ Remove the factor
-installed jumper connectin
terminals R and
RC if wires are connected to both of those terminals.
❑ For wirin
dia
rams, if needed, see pp 21-22.
❑ Loosen the terminal screws. Slip each wire beneath its matchin
terminal. Wraparound and strai
ht connections are both
acceptable, (see illustration). Ti
hten the terminals.
❑ Plu
the hole in the wall with insulation to help prevent drafts from adversel
affectin
thermostat operation.
M16425
R
W
Y
G
M4826
FOR WRAPAROUND
INSERTION STRIP
7/16 IN. (11 MM).
FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM).