A SERVICE OF

logo

Maximum British
Thermal Unit Rating
(BTU-Hr)
2925 2892 2812 2812 2797 2797 2797
HP 1200W Power
Supply
Part Number - AC
500172-B21
Operational Input
Voltage Range (Vrms)
100 to 240
Frequency Range
(Nominal) (Hz)
50/60
Nominal Input Voltage
(Vrms)
100 120 208 200 220 230 240
Maximum Rated Output
Wattage
800 900 1200 1200 1200 1200 1200
Nominal Input Current
(A rms)
9.7 9.0 7.0 6.8 6.4 9.1 5.9
Max Rated Input
Wattage Rating (Watts)
930 1034 1348 1348 1348 1348 1348
Max. Rated VA (Volt-
Amp)
970 1079 1406 1406 1406 1406 1406
Efficiency (%)at Max.
Rated Output Wattage
86 87 89 89 89 89 89
Power Factor
0.97 0.97 0.97 0.97 0.97 0.97 0.97
Leakage Current (mA)
0.42 0.50 0.83 0.87 0.92 0.96 1.00
Max. Inrush Current
(A peak)
30 30 30 30 30 30 30
Max. Inrush Current
duration (mS)
20 20 20 20 20 20 20
Maximum British
Thermal Unit Rating
(BTU-Hr)
3174 3530 4600 4600 4600 4600 4600
HP 1200W PSU 48VDC
Input Part Number
437573-B21
Input Voltage Range
(DCV)
36-72
Frequency Range
(Nominal) (Hz)
DC
Nominal Input Voltage
(Vrms)
36 48 72
Maximum Rated Output
Wattage
1200 1200 1200
Nominal Input Current
(A rms)
38 28 19
Max Rated Input Wattage
Rating (Watts)
1380 1350 1365
Max. Rated VA (Volt-
Amp)
1380 1350 1365
Efficiency (%)at Max.
Rated Output Wattage
87 89 88
Power Factor
N/A N/A N/A
Leakage Current (mA)
N/A N/A N/A
QuickSpecs
HP ProLiant DL385 Generation 6
Power Specifications
DA - 13360 Worldwide QuickSpecs — Version 9 — 10.23.2009