A SERVICE OF

logo

Service
14 333492B
Service
Cleaning / Repairing the Fluid
Section
NOTE: Do not disassemble the fluid and counting sec-
tions simultaneously. Confirm the fluid section is fully
assembled before removing the counting section.
1. Relieve pressure, page 8.
2. Close fluid shut off valve (L).
3. Remove nozzle (101) and extension (102).
4. Turn meter cap (17) counter-clockwise to unscrew
and remove it from the meter housing.
5. Remove seal (18) and piston assembly (19). If the
piston assembly sticks, lightly tap the housing
against a flat surface to loosen it (F
IG. 12).
6. Insert a screwdriver into the notch of the piston
assembly (19) and pry off the piston cover (19d).
See F
IG. 13. Remove all parts.
7. Clean the parts (19a-g) and blow them dry.
8. Reassemble the piston assembly (19) and install in
meter.
9. Install cover (17) on meter housing. Torque to 11-14
ft. lbs (14.9-18.9 N•m).
10. Install nozzle and extension assembly (101 and
102).
FIG. 10
FIG. 11
101
102
17
FIG. 12
FIG. 13
18
19
19
19d