Dimensional Diagrams
upper
chimney
cover
lower
chimney
cover
canopy
cabinet base
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
also consult cooktop
manufacturer's recommendation
2 3/4” min
15
3/8” max
23
5/8”
3 3/16”
36”
x
min & max ceiling height examples
x = 30"
min
7'
11 9/16"
max
9'
3/16"
x = 28"
min
7'
9 9/16"
max
8'
10 3/16"
x = 26"
min
7'
7 9/16"
max
8'
8 3/16"
x = 24"
min
7'
5 9/16"
max
8'
6 3/16"
upper
chimney
cover
ductless
lower
chimney
cover
canopy
cabinet base
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
also consult cooktop
manufacturer's recommendation
8
3/8”
min
15
3/8”
max
23
5/8”
36”
x
min & max ceiling height examples
x = 30"
min
8'
5 3/16"
max
9'
3/16"
x = 28"
min
8'
3 3/16"
max
8'
10 3/16"
x = 26"
min
8'
1 3/16"
max
8'
8 3/16"
x = 24"
min
7'
11 3/16"
max
8'
6 3/16"
12
1/2"
3
3/16”
3
1/2”
The ducted Diamante Isola chimney can be adjusted for ceilings between 7’ 5 9/16” and 9’ 3/16” depending on the distance between
the bottom of the hood and the cooktop (distance x in above DUCTED diagram). The ductless Diamante Isola chimney can be
adjusted for ceilings between 7’ 11 3/16” and 9’ 3/16” depending on the distance between the bottom of the hood and the cooktop
(distance x in above DUCTLESS diagram). For higher ceiling installations, the High Ceiling Chimney Kit includes an additional
support structure which adds 27 1/2" to the various ceiling heights in the figures above.
Ducted
Ducted Ductless
1
Ductless
* it is highly recommended that
professional style cooking always be
vented to the outside.
WARNING! Product specifications are subject to change without notification. Consult the installation instructions before you begin installing this rangehood.
Pre-Planning Your Installation - Important: Consult the installation
instructions before you begin installing this rangehood.
Ductless Installations*
For installations where ductwork is
impossible or highly impractical, a Ductless
Conversion Kit is available. A charcoal
filter, which attaches under the blower
assembly, absorbs smoke and odors. A
ductless diverter assembly directs the air
out to a lower chimney with vent grates cut
into the sides.
Make your ductrun as straight and short as possible. The ductrun should not exceed
35 equivalent feet if ducted with the required minimum of 6” round duct. Count 45º
angles as 3 feet, 90º elbows as 5 feet, and 90º flat elbows as 12 feet.
For best results, use no more than three 90° elbows. Make sure that there is a
minimum of 24” of straight duct between elbows if more than one is used. Do
not install two elbows together. If you must elbow right away, do it as far away
from the hood’s exhaust opening as possible.
Rev. 06/08