MTP SW6 • Remote Contol
Remote Control, cont’d
3-6
MTP SW6 • Remote Contol
3-7
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Input selection
N
The switcher supports 1-, 2-, and 3-digit numeric entries (1!, 02&, or 003%). The switcher reports all selections with 1-digit numbers.
N
The & select and the % select commands for video can be used interchangeably.
Select input
X! to
output
, video and audio
X!
! All
X!]
Select input
X!
video and audio to be the output.
Example:
1!
All1
]
Select input 1 video and audio.
Select input
X! to
output, video only
X!
& Vid
X!]
Select
X!
video (audio breakaway).
Example
(see 2nd Note, above):
5&
Vid5
]
Select input 5 video.
Select input
X! to
output, video only
X!
% Vid
X!]
Select
X!
video (audio breakaway).
Tie input
X! to output,
audio only
X!
$ Aud
X!]
Select
X!
audio (audio breakaway).
Example:
2$
Aud2
]
Select input 2 audio.
Command/response table for SIS commands
N
X!
= Input number
1 – 6
Command/response table for SIS commands (continued)
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Level adjustment
Set a level setting
EX!
*
X@
ILVL
}
Ilvl
X!
*
X@]
Set level setting to
X@
.
Increment level
adjustment
EX!
+ILVL
}
Ilvl
X!
*
X@]
Increase the level setting.
Decrement level
adjustment
EX!
ILVL
}
Ilvl
X!
*
X@]
Decrease the level setting.
Show level
EX!
ILVL
} X@]
Peaking adjustment
Set a peaking setting
EX!
*
X#
IPEK
}
Ipek
X!
*
X#]
Set peaking setting to
X#
.
Increment peaking
adjustment
EX!
+IPEK
}
Ipek
X!
*
X#]
Shift the image one pixel to the right.
Decrement peaking
adjustment
EX!
IPEK
}
Ipek
X!
*
X#]
Shift the image one pixel to the left.
Show peaking
EX!
IPEK
} X#]
N
X!
= Input number
1 – 6
X@
= Input level range 00 – 255
X#
= Input peaking range 0
– 65