DCP42‐en‐GB_V1.512/14
7
4. ControlModes
Therearefourcontrolmodesforthepowersupply:NORMAL,PRESET,SET,andREMOTECONTROL
modes.ThepowersupplyisfactorypresettoNormalModewithmaximumcurrentlevelCC.
4.1NormalMode
Thisisthefactorydefaultmode;thepowersupplyoutputVoltageandCurrentarecontrolledby
thedualactiongainknobs.
1. Pushtheknobstotogglethecoarseandfinetuning,noticethesubtlechangesin
brightnessoftherelatedLED.
2. Adjusttheknobstothedesiredvaluesusingcoarseandthenfinetuning.
3. Tocheckthepresetcurrentlevel,turntheCurrentKnoblightlyinanydirection.
4. Thedisplaywillresumeitsnormalbrightnessafterafewsecondstore‐affirmthe
adjustment.
4.2PresetMode
1. TherearethreepresetoutputsP1/P2/P3available.
2. PressthePresetbutton(1,2,or3)toenterthepresetmode(thebutton’slightwill
switchON).
3. Thepresetvaluesarefactorysetasshowninthetablebelowandareretainedevenafter
theunithas
beenpowereddown.
4. Theusercanchangetheseoutputsettingsusingthevoltageandcurrentknobs.
RecallNo. OutputVoltage OutputCurrent
P1 5V Maximum
P2 13.8V Maximum
P3 40VMaximum
4.3SetMode
EntertheSetModebypushingandholdingtheMENUbuttonfor3seconds.IntheSetModethe
usercanadjusttheΔV/Δtvalue,accesstheremoteControlmode,orperformaFactoryReset
recallfunction.Note:Ifnoselectionismade after10secondsthepowersupplydefaults
toits
priorsettings.
4.3.1SettingtheΔV/Δtvalue
a.PressandholdtheMENUbuttonfor3secondstoaccesstheSetMode.
b.TurntheVoltagecontrolknobuntilthepanelmeterdisplays“dudtSet”asshownbelowand
thenpresstheVoltagecontrolknobtoenter
theΔV/Δtsettingmode.
c.AdjusttheVoltageandCurrentcontrolknobsasdesiredtosettheΔV/Δtvalue.Furtherdetails
areprovidedinthededicatedsectionforΔV/Δtmodelaterinthisguide.
d.Whenfinished,presstheVoltagecontrolknobtoconfirmandreturntoSetmenu
e.Pressthe
MenukeytoexittheSetmenu
f.TostarttheΔV/Δtfunction,presstheSHIFTbuttonandthenpresstheΔV/Δtbuttontorun,
g.TostoptheΔV/Δtfunction,presstheSHIFTbuttonandthenpresstheΔV/Δtbuttonagain.