• Split Dual Host mode
Split single host mapping configuration
In the split single host mapping configuration, dual controllers inside a storage sled map to a single
compute sled.
The following enclosure configurations support split single host mapping.
• Four-bay chassis with two compute sleds—dual controllers inside a storage sled map to a half-width
compute sled.
• Four-bay chassis with one compute sled—dual controllers inside each storage sled map to the single
half-width compute sled.
• Three-bay chassis with one compute sled—dual controllers inside each storage sled map to the single
full-width compute sled.
NOTE: PowerEdge FX2s supports multiple split single host mapping configurations. You must select
the desired configuration based on your intended usage.
Figure 9. Split single host mapping configuration—four-bay chassis
Figure 10. Split single host mapping configuration—four-bay chassis (one compute sled)
Figure 11. Split single host mapping configuration—three-bay chassis
Split dual host mapping configuration
In the split dual host mapping configuration, dual controllers inside one storage sled are mapped to two
different compute sleds.
14