You can configure the server to start Compaq Utilities in four different ways:
Without remote console support; for example, to run Compaq Utilities from the server
console only
With remote console support using modems for dial-in access
With remote console support using a modem to dial a predetermined telephone number
With remote console support through a network connection (IP or IPX)
Table 3-18
ASR-2 Features
Features Definition
Software error recovery If enabled, ASR-2 is activated if the OS hangs or has a crash that
results in a lockup.
Software error recovery timeout Determines how long the server waits to enable ASR-2 after an OS
lockup
Standby recovery server option If enabled, ASR-2 activation initiates a switch to a standby recovery
server.
Standby recovery server port Port used to communicate with the recovery server.
Standby recovery timeout Determines how long the server waits to initiate switch after ASR-2
activation
Software error recovery boot option Allows the server to restart either into the OS or into Compaq
Utilities
Thermal shutdown If enabled, shuts down the server if a critical thermal error occurs
UPS shutdown If enabled, allows the server to perform a shutdown if a UPS is
activated
UPS shutdown threshold Determines how long the server waits to shut down after the UPS
is activated. If desired, this number should provide enough time for
an administrator to perform any necessary operations or to
gracefully shut down the server.