SOLUTIONS TO COMMON PROBLEMS
PROBLEM POSSIBLE CAUSES & SOLUTIONS
One valve does not
turn on, all others
work correctly.
Wiring to valve broken.
Solenoid faulty - test valve with good
one.
Program set for OFF watering time for
that valve.
Flow control on valve adjusted to off.
Solenoid port clogged in valve, clean wit
h
paper clip.
All valves do not
turn on
Controller is running on battery only.
Check that the outlet and transformer ar
e
working.
Controller Program switch is not set on
RUN.
Program set for no watering time.
Wiring to valves broken - check common
wire.
Excess water pressure.
One valve won't
shut off
Manually close flow adjustment screw.
Valve needs cleaning or repair.
Display shows: AC
A
C Power to controller is off. Check that
AC power is on, then check that the
transformer is working (use a
multimeter).
Display flashing a
zone #
The wire to the flashing station and
common wire are shorted. Check wiring
connections at the valve, at the controlle
r
and in between. Another cause is a
shorted solenoid - A good solenoid has
15-35 ohms resistance.
Start times not
correct
There could be an overlap of start times
between programs A, B, & C. Set Start
Time to a different time in one program.