TABLE 10: D1EB060 SUPERHEAT CHARGING (IMPERIAL)
OUTDOOR
TEMPERATURE
(°F)
SUPERHEAT AT COMPRESSOR SUCTION (°F)
AIRFLOW = 2,000 CFM
INDOOR WB TEMPERATURE (°F)
55 57 59 61 63 65 67 69 71 73 75
65 21.9 23.8 25.7 27.6 29.4 31.3 33.2 34.2 35.1 35.6 36.1
70 16.0 18.4 20.7 23.0 25.3 27.6 30.0 31.3 32.7 33.4 34.0
75 10.1 12.9 15.7 18.4 21.2 23.9 26.7 28.5 30.2 31.1 32.0
80 - 7.5 10.7 13.9 17.1 20.3 23.5 25.6 27.8 28.9 29.9
85 - - 5.6 9.3 12.9 16.6 20.2 22.8 25.3 26.6 27.9
90 - - - 7.6 10.6 13.6 16.7 19.8 22.9 24.4 26.0
95 - - - 5.9 8.3 10.7 13.1 16.7 20.4 22.2 24.0
100 - - - - 6.4 8.2 10.1 13.2 16.3 17.9 19.5
105 - - - - - 5.8 7.0 9.6 12.3 13.6 14.9
110 - - - - - - - 6.1 8.2 9.3 10.4
115 ----------5.8
TABLE 11: D1EB060 SUPERHEAT CHARGING (METRIC)
OUTDOOR
TEMPERATURE
(°C)
SUPERHEAT AT COMPRESSOR SUCTION (°C)
AIRFLOW = 0.94 M
3
/S
INDOOR WB TEMPERATURE (°C)
13 14 15 16 17 18 19 21 22 23 24
18 12.2 13.2 14.3 15.3 16.4 17.4 18.4 19.0 19.5 19.8 20.0
21 8.9 10.2 11.5 12.8 14.1 15.4 16.6 17.4 18.2 18.5 18.9
24 5.6 7.2 8.7 10.2 11.8 13.3 14.8 15.8 16.8 17.3 17.8
27 - 4.1 5.9 7.7 9.5 11.3 13.0 14.2 15.4 16.0 16.6
29 - - 3.1 5.2 7.2 9.2 11.2 12.6 14.1 14.8 15.5
32 - - - 4.2 5.9 7.6 9.3 11.0 12.7 13.6 14.4
35 - - - 3.3 4.6 5.9 7.3 9.3 11.3 12.3 13.3
38 - - - - 3.6 4.6 5.6 7.3 9.1 9.9 10.8
41 - - - - - 3.2 3.9 5.4 6.8 7.6 8.3
43 - - - - - - - 3.4 4.6 5.2 5.8
46 - - - - - - - - - - 3.2