Setting the Configuration Switch
The TriCode
®
receiver is factory set for Linear/Delta-3
TM
.
Locate the configuration switch and set it to the desired RF mode
of operation (Figures 2 and 3). Modes are as follows:
Linear/Delta-3
TM
: works with all “Linear/Delta-3
TM
” transmitters
transmitted at 310 MHz using 8-bits ID system.
Multi
TM
: works with all “Multi-Code
TM
” transmitters transmitted at
300 MHz using 10-bits ID system.
Stanley
TM
: works with all “Stanley
TM
radio” transmitters
transmitted at 310 MHz using 10-bits ID system.
Setting Output Relay Mode
The TriCode
®
receiver is factory set for momentary relay output
“MNT”.
• Momentary mode: The output relay will be on for .5 seconds
before turning off.
• Constant pressure mode: Output relay is continuously on
while receiving matching/valid ID code from transmitter. The
output relay will turn off immediately once receiver does not
receive a matching/valid ID code from the transmitter
(Figure 3).
NOTE: If constant pressure mode is desired, open front cover
and move mode jumper from “MNT” to “CST” (Figure 2).
Figure 3