A SERVICE OF

logo

SERVICING INSTRUCTIONS (continued)
14
Adjustments to be performed by
qualified technician only.
NOTE:
Brewer is pre-adjusted to deliver
1/2, 1 and/or 1-1/2 gallons of
coffee at a water pressure of 50
p.s.i. Use this procedure to
adjust the delivered volume to
suit local conditions.
Adjust only in small increments
to avoid large volume variations.
Recommend knob be turned no
more than one mark on the dial
plate at a time.
Moving the dial one mark will
change delivered volume by
approximately 6 oz.
BREW TIMER ADJUSTMENT
PRECAUTIONS: None
FREQUENCY: As required to adjust delivered volume
TOOLS: Small flathead screwdriver
Satellite or other container to calibrate volume
1. Press TANK HEATER switch to OFF.
2. Remove TIMER ACCESS COVER on front panel. Press
VOLUME SELECTOR to 1 GAL position.
3. Install an empty satellite and empty brew chamber.
4. Press START BREW switch. Brew should deliver 1 gallon
(128 fl. oz.). If adjustment is necessary, turn TIMER knob:
Turn CLOCKWISE to increase time;
Turn COUNTER-CLOCKWISE to decrease time.
Test after each adjustment. Be sure to empty satellite before
each test.
5. Turn TANK HEATER switch ON.
6. Allow the brewer to come up to brewing temperature, then
perform a test brew. Check delivered volume. Readjust as
necessary.
7. Reinstall TIMER ACCESS COVER.
When desired volume is achieved, procedure is complete.
663 76061 Owners Manual for 9102A Single Satellite Brewer