A SERVICE OF

logo

357
Chapter 4, Description of Fields
Fields
Reg Period
This field sets the interval for timer-based registrations. The default value for this
field, 29, provides registration intervals of approximately 12 seconds. Selecting
higher numbers increases this interval.
GPIB Example
OUTPUT 714;"CDMA:CELL:CONF:TREG:PER 29"
sets the timer-based registration period to 29.
Operating Considerations
The range of values that can be entered in this field is 29 through 85.
See Also
Timer Reg
field description, on page 428
Screens Where Field is Present
CDMA CELL SITE CONFIGURATION
Table 15 Timer-based registration time periods
Reg Period field setting Registration Period
29 12.16
30 14.48
331 17.2
32 20.48
38 57.92
62 3707.2