![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/84/d840f80e-0892-4ff2-9f1b-44856003ab0c/d840f80e-0892-4ff2-9f1b-44856003ab0c-bg1e.png)
© 3M 1999 3M
™
Multimedia Projector MP8740
TECHNICAL
Serial Command Codes
All numbers in this document are in Hexadecimal. You must send at the same communication setting
as the projector and use a null modem serial cable to connect to the projector.
There are four types of messages for the MP8740, 1) ASK, 2) REPLY, 3) SET and 4) DEFAULT.
Ask Code:
User:
20 XX
XX is the attribute you are checking.
Projector:
1Y XX Y bytes of data
This is a reply code. The Y is the number of extra bytes that come after the command.
The XX is the same as in the Ask code.
Set Code:
User:
3Y XX Y bytes of data
XX is the attribute you are checking. The Y is the number of bytes for the data.
Projector:
1Y XX Y bytes of data
This is a reply code. The Y is the number of extra bytes that come after the command.
The XX is the same as in the Set code.
Default Code:
User:
40 XX
XX is the attribute you are checking.
Projector:
1Y XX Y bytes of data
This is a reply code. The Y is the number of extra bytes that come after the command.
The XX is the same as in the Ask code.
Errors:
For an error, the projector will reply with the same code that was sent but with a 0 in the first nibble.