Trunk Group Members: Assign trunk ports to the Trunk Group. Up to 255 ports can be
assigned to each ISDN Trunk Group. The Sig Grp prompt will display the signaling group after
the Trunk Group is created and assigned to the Signaling Group.
Figure 5. Assign trunk Group Members
6. Hicom Configurations:
The following listing of Command Line Interface (CLI) text is intended to be an accurate
representation of the actual administrative visuals for implementing the translations
required for the Hicom 300.
Typical Cabinet Configuration:
<dis-bcsu:tbl; (Displays Board Configuration Switching Unit)
H500: AMO BCSU STARTED
ADDRESS |NOM. BOARD TYPE V/R| |ACTUAL BOARD |LWV|FID|FIRMWARE|BD STATUS |CCN|
----------+-----------------------------------------+-+----------------------+------------+-------------+------------------+-----+
1. 1. 37 | Q2161-X DSC80 | | Q2161-X | 1 | 2 | D961-D | READY |1 |
1. 1. 49 | Q2146-X SLMA2 | | Q2146-X | 1 | 0 | -11 - | READY |24 |
1. 1. 55 | Q2485-X TMC16P | | Q2485-X | 1 | 0 | D429-B | READY |16 |
1. 1. 61 | Q2158-X SLMO24 R | | Q2158-X | 1 | 0 | -05 - | READY |24 |
1. 1. 67 | Q2158-X SLMO24 R | | Q2158-X | 1 | 0 | -05 - | READY |24 |
1. 1. 73 | FREE | | FREE | | | | | |
1. 1. 79 | FREE | | FREE | | | | |0 |
1. 1. 85 | Q2452-X TMDID | | Q2452-X | 1 | 0 | B008-D | READY |8 |
1. 1. 91 | FREE | | FREE | | | | |0 |
1. 1. 97 | Q2233-X SIUX | | Q2233-X | 1 | 2 | D802-B | READY |8 |
1. 1.103| FREE | | FREE | | | | |0 |